Eaton BRP115AFC Circuit Breaker, AFCI, Combination, Type BR, 15 A, 1-Pole, 120/240 VAC, Long Time

2531010

Eaton BRP115AFC Circuit Breaker, AFCI, Combination, Type BR, 15 A, 1-Pole, 120/240 VAC, Long Time

Item Code: 2531010
Manufacturer EATON INDUSTRIES CANADA

Description

An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when the arc fault is detected. As of January 1, 2015, the Canadian Electrical Code now requires that all branch circuits that supply 125 V, single-phase, 15 and 20 A receptacle outlets installed in dwelling unit shall be protected by a combination arc fault circuit interrupter(s) (series arc and parallel arc detection).

Specifications

UNSPSC Code

35.353.353

Weight

0.46lb

Height

1.25in

Width

3.5in

Length

6.25in

Actuator Type

Magnetic Thermal

Current Rating

15 A

Dimensions

3-1/2 in L x 3-1/2 in W x 1-1/4 in H

Interrupt Rating

10 kA

Number of Phases

1

Number Of Poles

1

Suitable For

CPM CPL CBRPM CBRPL Load Center

Terminal Type

Plug-In

Trip Type

Long Time Instantaneous

Type

AFCI Combination Type BR

Voltage Rating

120/240 Vac

Wire Size

14 to 4 AWG

Call for price
Starting from
CAD 114.95 / EA
/
- +
Your Pick Up branch is 1000 Parkinson Road, Woodstock
Compare

Eaton BRP115AFC Circuit Breaker, AFCI, Combination, Type BR, 15 A, 1-Pole, 120/240 VAC, Long Time

2531010

Eaton BRP115AFC Circuit Breaker, AFCI, Combination, Type BR, 15 A, 1-Pole, 120/240 VAC, Long Time

Item Code: 2531010
Manufacturer EATON INDUSTRIES CANADA

Description

An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when the arc fault is detected. As of January 1, 2015, the Canadian Electrical Code now requires that all branch circuits that supply 125 V, single-phase, 15 and 20 A receptacle outlets installed in dwelling unit shall be protected by a combination arc fault circuit interrupter(s) (series arc and parallel arc detection).

Specifications

UNSPSC Code

35.353.353

Weight

0.46lb

Height

1.25in

Width

3.5in

Length

6.25in

Actuator Type

Magnetic Thermal

Current Rating

15 A

Dimensions

3-1/2 in L x 3-1/2 in W x 1-1/4 in H

Interrupt Rating

10 kA

Number of Phases

1

Number Of Poles

1

Suitable For

CPM CPL CBRPM CBRPL Load Center

Terminal Type

Plug-In

Trip Type

Long Time Instantaneous

Type

AFCI Combination Type BR

Voltage Rating

120/240 Vac

Wire Size

14 to 4 AWG

Call for price
Starting from
CAD 114.95 / EA
/
- +